Azimuth is a semi-closed cyclical
circuit breathing apparatus , giving constant and controlled flow.
The gas mixture follows a single direction circular path utilizing
two different separated way of circulation, to and from the breathing
bag.
Especially, the constant flow of gas mixture coming
from the nitrox cylinders, by means of the dosing group goes in
to the inhalation breathing bag and reaches the corresponding pressure
to the diving depth.
The diver breathes the gas mixture contained in the inhalation breathing
bag trough the corrugated hose connected to it, via the mouthpiece
assembled on the four-way valve and exhals the gases produced by
the breathing process in to the exhalation hose connected to the
exhalation breathing bag.
The excess pressure generated by the constant flow is vented from
the relief valve connected to the bag itself by means of a short
flexible hose.
Gases from the exhalation breathing bag go
in to the filter and once purified from the carbon-dyoxyde, enter
into the inhalation breathing bag.
The quantity of Oxygen methabolized during the breathing process
is re-integrated by the oxigen in the gas mixture flow continously
conducted in the inhalation breathing bag.
|